P-3A Series
  
Type No.
TF
Cut-off
Temp.
TH/TC
TM/Tm
Ir
Ur
Safety Standard
( Approved Applying )
UL
CUL
VDE
MITI
PSE
CCC
P0-3A
84oC
822oC
55oC
180oC
3A
250V
 
P1-3A
102oC
982oC
63oC
180oC
3A
250V

P2-3A

115oC
1113oC
75oC
180oC
3A
250V
P3-3A
125oC
1222oC
85oC
180oC
3A
250V
P4-3A
130oC
1262oC
90oC
180oC
3A
250V
P5-3A
135oC
1313oC
90oC
180oC
3A
250V
P7-3A
150oC
1452oC
100oC
180oC
3A
250V
 
P9-3A
138oC
1352oC
95oC
180oC
3A
250V


Pic and Size

產品實物放大圖

Size:G(mm)
 
A
B
C
D
10.00.5
383
0.600.02
3.00.1

EXPLANATION OF TECHNICAL TERMS
TF - Rated functioning temperature: The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection current.The tolerance according to IEC691 is from +0 to -10degree.(With Japan Electrical Appliance and Material Law, on the other hand, they must function in the tolerance range of +/-7degree C.).
Fusing(Cut)-off temperature: The Fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1degree per minute and a detective current 100mA or less.
TH/TC-Holding temperature: The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours.this rating is required by safety standards based on IEC691.
TM/Tm - Maximum temperature limit: The maximum temperature at which a Thermal Cutoff can be maintained for 10 minutes without reclosing.This rating is required by safety standards based on IEC691
Ir - Rated current: The allowable maximum current which a Thermal Cutoff is able to carry
Ur - Rated voltage: The allowable maximum voltage which a Thermal Cutoff is able to be applied.

BACK

© 2017 Cotech Electronics Co., Ltd. All Rights Reserved