| A-1A | P-1A | B-1A | RH-1A |

  P-1A
  
Type No.
TF
Cut-off
Temp.
TH/TC
TM/Tm
Ir
Ur
Safety Standard
( Approved Applying )
UL
CUL
VDE
MITI
PSE
CCC
P1-1A
102oC
982oC
76oC
180oC
1A
250V
0.5A

P2-1A

115oC
1113oC
83oC
180oC
1A
250V
0.5A
P3-1A
125oC
1222oC
97oC
180oC
1A
250V
0.5A
P4-1A
130oC
1262oC
102oC
180oC
1A
250V
0.5A
P5-1A
135oC
1313oC
105oC
180oC
1A
250V
0.5A
P7-1A
150oC
1452oC
120oC
180oC
1A
250V
 
0.5A
P9-1A
138oC
1352oC
108oC
180oC
1A
250V
0.5A
P10-1A
117oC
1133oC
88oC
180oC
1A
250V
0.5A

Pic and Size

產品實物放大圖


Size:G(mm)
 
A
B
C
D
6.50.5
383
0.530.02
2.10.1

EXPLANATION OF TECHNICAL TERMS
TF - Rated functioning temperature: The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection current.The tolerance according to IEC691 is from +0 to -10degree.(With Japan Electrical Appliance and Material Law, on the other hand, they must function in the tolerance range of +/-7degree C.).
Fusing(Cut)-off temperature: The Fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1degree per minute and a detective current 100mA or less.
TH/TC-Holding temperature: The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours.this rating is required by safety standards based on IEC691.
TM/Tm - Maximum temperature limit: The maximum temperature at which a Thermal Cutoff can be maintained for 10 minutes without reclosing.This rating is required by safety standards based on IEC691
Ir - Rated current: The allowable maximum current which a Thermal Cutoff is able to carry
Ur - Rated voltage: The allowable maximum voltage which a Thermal Cutoff is able to be applied.